FFBEAST · DEFINITIONS

Every input explained.
Every symbol defined.

Definitions for every calculator input, result and chart. Each equation includes its symbols and units.

1. Project targets

Target full torque [Nm]

The maximum positive driving torque that should remain available at the target full-torque speed.

Default input: 10 Nm. The model deliberately caps available torque at this target; it does not show the absolute physical maximum of the motor.

← Back to calculator

Target self-rotation speed [rpm]

The speed the wheel should reach under FFB torque, for example during self-alignment or countersteer in drifting. Default input: 300 rpm.

This is a loaded operating requirement, not a no-load speed. The specified minimum self-rotation torque must still be available at this speed.

← Back to calculator

Target full-torque speed [rpm]

The speed at which the full target torque should still be available. I use 10 Nm at 200 rpm, because I regard 200 rpm as the maximum wheel speed I can physically reach during rapid hand movements.

This is an input target for the torque–speed characteristic. It is distinct from the calculated full-torque corner speed, which depends on supply voltage, motor parameters and current limits.

← Back to calculator

Minimum torque at target self-rotation speed [Nm]

The minimum positive driving torque required at the target self-rotation speed. I use 2 Nm at 300 rpm: this provides a small margin above the torque needed to turn my wheel with its attached button box and no additional load.

The required torque depends on wheel inertia, friction and desired acceleration. The calculator does not solve the wheel acceleration dynamics.

← Back to calculator

2. Motor measurements

Torque constant Kt [Nm/A]

Kt relates torque to torque-producing current:

T = Kt · Iq
T
Motor torque [Nm]
Kt
Torque constant in the current-amplitude convention [Nm/A]
Iq
Torque-producing current amplitude [A]

The default input of 0.56 Nm/A was experimentally determined for the project motor. It refers to the current-amplitude convention used by the model. Do not use an RMS-based constant without converting its current convention.

Torque was measured with a digital torque wrench in Peak mode. Two phase currents were read from the MKS XDrive Mini through ST-Link, and the third was inferred from Kirchhoff’s current law. A peak torque measurement does not establish a continuous torque rating.

← Back to calculator

Line-to-line resistance [Ω]

Measure between two motor phase wires. This field expects line-to-line resistance, not one winding’s resistance to the internal star point.

Disconnect the motor from the controller. Measure each of the three wire pairs with the motor stationary and at a known temperature. Results should be similar. Significant differences can indicate a damaged motor, but first rule out measurement error, poor contacts or faulty connections.

The project used a four-wire measurement at 1 A to reduce the effect of leads and contacts. Default input: 0.35 Ω.

For a symmetrical star-connected motor, line-to-line resistance is twice one phase winding’s resistance. The model formulas already include this conversion: enter the measurement without dividing it by two. Other winding connections or current conventions require the model to be checked.

← Back to calculator

Winding temperature rise [°C]

Default input: 50°C. The project assumes a resistance measurement at 25°C and an intended maximum magnet operating temperature of 75°C. The difference, 75 − 25 = 50°C, is used as the temperature-rise assumption.

The calculator applies that rise to winding resistance:

Rhot = Rmeasured · (1 + 0.00393 · ΔT)
Rhot
Temperature-adjusted line-to-line winding resistance [Ω]
Rmeasured
Line-to-line resistance at the measurement temperature [Ω]
ΔT
Winding temperature rise relative to the measurement temperature [°C]
0.00393
Copper temperature coefficient used in the resistance correction [1/°C]

For 0.35 Ω and a 50°C rise, the calculated resistance is 0.418775 Ω.

The 75°C limit is the project owner’s assumption, not a universal magnet rating. Winding and magnet temperatures can differ. This correction does not predict either temperature, establish a safe duty cycle or verify magnet temperature.

← Back to calculator

3. Controller parameters

Current at 100% Power Limit [A]

The controller current represented by 100% FFBeast Power Limit in your hardware and firmware configuration.

The project uses 37 A with Amplifier Sense Gain 80 V/V. If a different gain is used, enter the corresponding current scale. Verify the scaling for your controller.

This value is the denominator in Required Power Limit and caps the modeled current. It is not a calculated operating current or a continuous thermal rating.

← Back to calculator

PWM voltage utilization [%]

This factor converts selected DC supply voltage to the voltage budget used by the loaded SVPWM model:

Ueff = Usupply · PWM
Ueff
Available motor voltage budget in the model convention [V]
Usupply
Selected DC supply voltage [V]
PWM
Voltage utilization factor, entered as percent but used as a fraction (85% = 0.85) [dimensionless]

For example, 85% utilization with a 36 V supply gives a calculated budget of 30.6 V. This is voltage utilization, not controller energy efficiency or a commanded fixed PWM duty cycle.

← Back to calculator

Power-stage efficiency [%]

Default input: 95%. Motor electrical input, approximated as mechanical output plus copper losses, is divided by this efficiency to estimate power-stage input. This is a design assumption, not an efficiency measurement at every operating point.

← Back to calculator

4. Supply voltage

Minimum required supply voltage [V]

The calculated minimum DC voltage required to satisfy both specified torque–speed conditions.

Kv,eq = 9.55 / Kt
Kv,eq
Equivalent speed constant used by this model [rpm/V]
Kt
Torque constant in the current-amplitude convention [Nm/A]
9.55
Approximation 60/(2π) for the matched SI-to-rpm speed conversion [rpm/(rad/s)]
Ureq,full = 1.155 · nfull / Kv,eq + 0.866 · (Ttarget / Kt) · Rhot
Ureq,full
Motor-model voltage required for the full-torque operating point [V]
nfull
Target full-torque speed entered in the calculator [rpm]
Kv,eq
Equivalent speed constant used by this model [rpm/V]
Ttarget
Target full torque [Nm]
Kt
Torque constant in the current-amplitude convention [Nm/A]
Rhot
Temperature-adjusted line-to-line winding resistance [Ω]
0.866
Conversion factor √3/2 for the model current and line-to-line voltage conventions [dimensionless]
1.155
Voltage-convention conversion factor 2/√3 [dimensionless]
Ureq,self = 1.155 · nself,target / Kv,eq + 0.866 · (Tmin / Kt) · Rhot
Ureq,self
Motor-model voltage required for minimum torque at the target self-rotation speed [V]
nself,target
Target self-rotation speed entered in the calculator [rpm]
Kv,eq
Equivalent speed constant used by this model [rpm/V]
Tmin
Minimum torque at the target self-rotation speed [Nm]
Kt
Torque constant in the current-amplitude convention [Nm/A]
Rhot
Temperature-adjusted line-to-line winding resistance [Ω]
0.866
Conversion factor √3/2 for the model current and line-to-line voltage conventions [dimensionless]
1.155
Voltage-convention conversion factor 2/√3 [dimensionless]
Usupply,min = max(Ureq,full; Ureq,self) / PWM
Usupply,min
Minimum required DC supply voltage [V]
Ureq,full
Motor-model voltage required for the full-torque operating point [V]
Ureq,self
Motor-model voltage required for minimum torque at the target self-rotation speed [V]
PWM
Voltage utilization factor, entered as percent but used as a fraction (85% = 0.85) [dimensionless]
max(…)
Select the largest argument; all arguments have the same unit [same as its arguments]

Both required voltages combine back-EMF, which rises with speed, and the resistive winding drop, which depends on torque-producing current and resistance. The larger requirement is divided by voltage utilization to give the required DC supply voltage. More detail is available in the selection algorithm.

← Back to calculator

Selected supply voltage [V]

The supply voltage you choose to evaluate. Enter a value or select 12, 24 or 36 V. This is an input; the minimum required voltage is a separate calculated result shown beside the selector and in the headline.

You can select less than the calculated minimum to compare performance. Hardware voltage ratings and regenerative energy handling require separate verification.

← Back to calculator

5. Performance results

Stall torque — stationary wheel [Nm]

The calculated torque with the wheel stationary, at 0 rpm. It is limited by target full torque, controller current and voltage available across winding resistance.

Iavailable = min(Ttarget / Kt, Icontroller,max, Ueff / (0.866 · Rhot))
Iavailable
Available torque-producing current after all model limits [A]
Ttarget
Target full torque [Nm]
Kt
Torque constant in the current-amplitude convention [Nm/A]
Icontroller,max
Controller current corresponding to 100% Power Limit [A]
Ueff
Available motor voltage budget in the model convention [V]
Rhot
Temperature-adjusted line-to-line winding resistance [Ω]
0.866
Conversion factor √3/2 for the model current and line-to-line voltage conventions [dimensionless]
min(…)
Select the smallest argument; all arguments have the same unit [same as its arguments]
Tstall = min(Ttarget, Kt · Iavailable)
Tstall
Available torque with the wheel stationary [Nm]
Ttarget
Target full torque [Nm]
Kt
Torque constant in the current-amplitude convention [Nm/A]
Iavailable
Available torque-producing current after all model limits [A]
min(…)
Select the smallest argument; all arguments have the same unit [same as its arguments]

This is torque capability at standstill, not a continuous holding torque rating.

← Back to calculator

Torque at target full-torque speed [Nm]

The torque available at the speed entered in Target full-torque speed. With 200 rpm entered, this result shows the available torque at 200 rpm.

Tavailable(nfull) = max(0, min(Tstall, Kt · (Ueff − 1.155 · nfull / Kv,eq) / (0.866 · Rhot)))
Tavailable
Available positive driving torque at the stated speed [Nm]
nfull
Target full-torque speed entered in the calculator [rpm]
Tstall
Available torque with the wheel stationary [Nm]
Kt
Torque constant in the current-amplitude convention [Nm/A]
Ueff
Available motor voltage budget in the model convention [V]
Kv,eq
Equivalent speed constant used by this model [rpm/V]
Rhot
Temperature-adjusted line-to-line winding resistance [Ω]
0.866
Conversion factor √3/2 for the model current and line-to-line voltage conventions [dimensionless]
1.155
Voltage-convention conversion factor 2/√3 [dimensionless]
max(…)
Select the largest argument; all arguments have the same unit [same as its arguments]
min(…)
Select the smallest argument; all arguments have the same unit [same as its arguments]

Compare the result with Target full torque. A lower result means the selected supply cannot provide the requested torque at that speed.

← Back to calculator

Torque at target self-rotation speed [Nm]

The positive driving torque available at Target self-rotation speed. Compare it with Minimum torque at target self-rotation speed.

Tavailable(nself,target) = max(0, min(Tstall, Kt · (Ueff − 1.155 · nself,target / Kv,eq) / (0.866 · Rhot)))
Tavailable
Available positive driving torque at the stated speed [Nm]
nself,target
Target self-rotation speed entered in the calculator [rpm]
Tstall
Available torque with the wheel stationary [Nm]
Kt
Torque constant in the current-amplitude convention [Nm/A]
Ueff
Available motor voltage budget in the model convention [V]
Kv,eq
Equivalent speed constant used by this model [rpm/V]
Rhot
Temperature-adjusted line-to-line winding resistance [Ω]
0.866
Conversion factor √3/2 for the model current and line-to-line voltage conventions [dimensionless]
1.155
Voltage-convention conversion factor 2/√3 [dimensionless]
max(…)
Select the largest argument; all arguments have the same unit [same as its arguments]
min(…)
Select the smallest argument; all arguments have the same unit [same as its arguments]

The project requirement is:

Tavailable(300 rpm) ≥ 2 Nm
Tavailable
Available positive driving torque at the stated speed [Nm]

This is torque at the specified speed, not a calculated speed.

← Back to calculator

Full-torque corner speed [rpm]

The calculated speed above which voltage limiting reduces available torque below the torque available with the wheel stationary.

ncorner = max(0, (Ueff − 0.866 · (Tstall / Kt) · Rhot) · Kv,eq / 1.155)
ncorner
Calculated full-torque corner speed [rpm]
Ueff
Available motor voltage budget in the model convention [V]
Tstall
Available torque with the wheel stationary [Nm]
Kt
Torque constant in the current-amplitude convention [Nm/A]
Rhot
Temperature-adjusted line-to-line winding resistance [Ω]
Kv,eq
Equivalent speed constant used by this model [rpm/V]
0.866
Conversion factor √3/2 for the model current and line-to-line voltage conventions [dimensionless]
1.155
Voltage-convention conversion factor 2/√3 [dimensionless]
max(…)
Select the largest argument; all arguments have the same unit [same as its arguments]

This boundary changes with supply voltage and motor parameters. It can be above or below the input target full-torque speed.

← Back to calculator

Self-rotation speed at minimum torque [rpm]

The maximum calculated speed at which the wheel can still provide the specified minimum torque. For a 2 Nm minimum, it is the speed available while retaining at least 2 Nm.

nself = max(0, (Ueff − 0.866 · (Tmin / Kt) · Rhot) · Kv,eq / 1.155)
nself
Maximum self-rotation speed retaining the specified minimum torque [rpm]
Ueff
Available motor voltage budget in the model convention [V]
Tmin
Minimum torque at the target self-rotation speed [Nm]
Kt
Torque constant in the current-amplitude convention [Nm/A]
Rhot
Temperature-adjusted line-to-line winding resistance [Ω]
Kv,eq
Equivalent speed constant used by this model [rpm/V]
0.866
Conversion factor √3/2 for the model current and line-to-line voltage conventions [dimensionless]
1.155
Voltage-convention conversion factor 2/√3 [dimensionless]
max(…)
Select the largest argument; all arguments have the same unit [same as its arguments]

If that torque is unavailable even with the wheel stationary, the result is marked Not achievable. If the minimum torque is set to zero, the result is the zero-torque speed boundary of the loaded SVPWM model. The status still checks whether the requested self-rotation speed is reachable; this is distinct from the separate six-step no-load estimate.

← Back to calculator

No-load speed — six-step estimate [rpm]

The idealized rotational speed without external shaft load, calculated separately for overmodulation/six-step:

n0 = (1.103 / 1.155) · Usupply · Kv,eq
n0
Idealized no-load speed in the six-step estimate [rpm]
Usupply
Selected DC supply voltage [V]
Kv,eq
Equivalent speed constant used by this model [rpm/V]
1.155
Voltage-convention conversion factor 2/√3 [dimensionless]
1.103
Six-step voltage-factor approximation 2√3/π [dimensionless]

This is not taken from the loaded SVPWM torque curve. It does not imply that loaded torque remains available at that speed.

← Back to calculator

Temperature-adjusted resistance [Ω]

The measured resistance corrected for the specified temperature rise:

Rhot = Rmeasured · (1 + 0.00393 · ΔT)
Rhot
Temperature-adjusted line-to-line winding resistance [Ω]
Rmeasured
Line-to-line resistance at the measurement temperature [Ω]
ΔT
Winding temperature rise relative to the measurement temperature [°C]
0.00393
Copper temperature coefficient used in the resistance correction [1/°C]

This value is used for resistive voltage drop and copper losses. It is a calculation result, not another measurement input.

← Back to calculator

Available voltage budget [V]

The selected DC supply voltage multiplied by the voltage utilization fraction:

Ueff = Usupply · PWM
Ueff
Available motor voltage budget in the model convention [V]
Usupply
Selected DC supply voltage [V]
PWM
Voltage utilization factor, entered as percent but used as a fraction (85% = 0.85) [dimensionless]

For 36 V and 85% utilization, the calculated budget is 30.6 V. This quantity is compared internally against back-EMF plus winding voltage drop. It is not a specified phase RMS voltage or an energy-efficiency-adjusted supply voltage.

← Back to calculator

6. Supply power, current and losses

Total required supply power [W]

Calculated DC supply power at the selected achievable operating point, before adding a design margin:

PDC = Pmech + PCu + Pdriver + Pelectronics
PDC
Total DC supply power draw before the design margin [W]
Pmech
Mechanical output power [W]
PCu
Total copper losses in the three windings [W]
Pdriver
Estimated controller power-stage losses [W]
Pelectronics
Fixed controller electronics and auxiliary power draw [W]
PDC = (Pmech + PCu) / η + Pelectronics
PDC
Total DC supply power draw before the design margin [W]
Pmech
Mechanical output power [W]
PCu
Total copper losses in the three windings [W]
η
Controller power-stage efficiency used as a fraction (95% = 0.95) [dimensionless]
Pelectronics
Fixed controller electronics and auxiliary power draw [W]

This includes mechanical output, copper losses, assumed controller power-stage losses and fixed electronics draw. It is not a supply nameplate rating or the global maximum over all speeds.

← Back to calculator

Supply current draw [A]

Calculated current drawn from the selected DC supply:

IDC = PDC / Usupply
IDC
DC supply current before the design margin [A]
PDC
Total DC supply power draw before the design margin [W]
Usupply
Selected DC supply voltage [V]

This is DC input current, not motor phase current or Iq. The 36 V example gives 9.19 A.

← Back to calculator

Operating point [Nm / rpm]

The torque and speed used together for the power calculation:

Twork = Tstall
Twork
Torque at the power-calculation operating point [Nm]
Tstall
Available torque with the wheel stationary [Nm]
nwork = min(nfull, ncorner)
nwork
Speed at the power-calculation operating point [rpm]
nfull
Target full-torque speed entered in the calculator [rpm]
ncorner
Calculated full-torque corner speed [rpm]
min(…)
Select the smallest argument; all arguments have the same unit [same as its arguments]

This selects an achievable point in the model; it does not search the full speed range for maximum power.

When supply voltage is insufficient

The power calculation uses a lower speed at which the modeled torque remains available. For the 12 V example it uses approximately 10 Nm at 55 rpm rather than the requested 200 rpm. That lower power belongs to reduced performance. Higher power can occur elsewhere as torque falls and speed rises.

← Back to calculator

Torque-producing current [A]

The current used to calculate losses after applying target, controller and standstill voltage limits:

Iwork = min(Ttarget / Kt, Icontroller,max, Ueff / (0.866 · Rhot))
Iwork
Torque-producing current at the power operating point [A]
Ttarget
Target full torque [Nm]
Kt
Torque constant in the current-amplitude convention [Nm/A]
Icontroller,max
Controller current corresponding to 100% Power Limit [A]
Ueff
Available motor voltage budget in the model convention [V]
Rhot
Temperature-adjusted line-to-line winding resistance [Ω]
0.866
Conversion factor √3/2 for the model current and line-to-line voltage conventions [dimensionless]
min(…)
Select the smallest argument; all arguments have the same unit [same as its arguments]

It corresponds to the available stationary-wheel torque and may be lower than the requested target current.

← Back to calculator

Mechanical power [W]

Mechanical output at the selected operating point:

Pmech = Twork · 2π · nwork / 60
Pmech
Mechanical output power [W]
Twork
Torque at the power-calculation operating point [Nm]
nwork
Speed at the power-calculation operating point [rpm]
π
Mathematical constant pi, approximately 3.14159 [dimensionless]
60
Seconds per minute, used when converting rpm to rad/s [s/min]

At standstill, mechanical power is zero even when the motor produces a substantial holding torque.

← Back to calculator

Copper losses [W]

Resistive losses in all three windings:

PCu = 0.75 · Iwork² · Rhot
PCu
Total copper losses in the three windings [W]
Iwork
Torque-producing current at the power operating point [A]
Rhot
Temperature-adjusted line-to-line winding resistance [Ω]
0.75
Three-phase copper-loss factor for current amplitude and line-to-line resistance (3/4) [dimensionless]

The coefficient follows the current-amplitude and measured line-to-line resistance conventions for the symmetrical star-connected motor. Losses increase with the square of current.

← Back to calculator

Power-stage losses [W]

Estimated controller power-stage losses:

Pdriver = (1 / η − 1) · (Pmech + PCu)
Pdriver
Estimated controller power-stage losses [W]
η
Controller power-stage efficiency used as a fraction (95% = 0.95) [dimensionless]
Pmech
Mechanical output power [W]
PCu
Total copper losses in the three windings [W]

Fixed electronics draw is added separately. Constant efficiency is an assumption and does not reproduce every real operating point.

← Back to calculator

Electronics power draw [W]

The fixed power used by controller electronics and the auxiliary supply. This is the value entered in Electronics power draw. It is added to motor power and controller power-stage losses:

PDC = Pmech + PCu + Pdriver + Pelectronics
PDC
Total DC supply power draw before the design margin [W]
Pmech
Mechanical output power [W]
PCu
Total copper losses in the three windings [W]
Pdriver
Estimated controller power-stage losses [W]
Pelectronics
Fixed controller electronics and auxiliary power draw [W]

Pelectronics is added separately, after power-stage efficiency is applied to motor input power. It is also included at standstill. The project input is 5 W.

← Back to calculator

Power draw at standstill [W]

Estimated DC draw at the same modeled holding current, with the wheel stationary:

Pstandstill = PCu / η + Pelectronics
Pstandstill
DC power draw with the wheel stationary at the modeled holding current [W]
PCu
Total copper losses in the three windings [W]
η
Controller power-stage efficiency used as a fraction (95% = 0.95) [dimensionless]
Pelectronics
Fixed controller electronics and auxiliary power draw [W]

Mechanical power is zero, but winding losses, controller losses and electronics consumption remain. This detail result does not include an extra 20% margin.

← Back to calculator

7. FFBeast firmware setting

Required Power Limit [%]

This result converts target full torque into the FFBeast current-limit setting using measured Kt and the configured current at 100% Power Limit:

Iq,target = Ttarget / Kt
Iq,target
Current required for the target full torque [A]
Ttarget
Target full torque [Nm]
Kt
Torque constant in the current-amplitude convention [Nm/A]
Power Limit = 100 · Iq,target / Icontroller,max
Power Limit
Required FFBeast firmware current-limit setting [%]
Iq,target
Current required for the target full torque [A]
Icontroller,max
Controller current corresponding to 100% Power Limit [A]
100
Percentage scale: 100% represents the full configured current scale [%]

For Ttarget = 10 Nm, Kt = 0.56 Nm/A and Icontroller,max = 37 A, required current is 17.86 A and the setting is 48.26%. These are calculated example results, not default inputs.

A value above 100% means the requested torque exceeds the configured controller current limit. Voltage must also be sufficient at the required speed. Power Limit is not a percentage of the supply rated current or a thermal safety rating.

← Back to calculator

8. Charts

Torque vs. speed

The horizontal axis is wheel speed [rpm]; the vertical axis is available positive driving torque [Nm]. The green line stays flat while full target torque can be maintained. When voltage is insufficient to retain that torque at increasing speed, torque falls.

If current or voltage already limits torque with the wheel stationary, the flat portion starts below the requested target. The amber horizontal line marks minimum self-rotation torque.

← Back to calculator

Required supply voltage vs. torque

The horizontal axis is torque [Nm]; the vertical axis is required DC supply voltage [V]. Each curve is the voltage requirement at 0 rpm, the target full-torque speed or the target self-rotation speed:

Ureq = 1.155 · n / Kv,eq + 0.866 · Iq · Rhot
Ureq
Required voltage in the motor-model convention [V]
n
Wheel rotational speed [rpm]
Kv,eq
Equivalent speed constant used by this model [rpm/V]
Iq
Torque-producing current amplitude [A]
Rhot
Temperature-adjusted line-to-line winding resistance [Ω]
0.866
Conversion factor √3/2 for the model current and line-to-line voltage conventions [dimensionless]
1.155
Voltage-convention conversion factor 2/√3 [dimensionless]
Usupply,req(T,n) = Ureq(T,n) / PWM
Usupply,req
DC supply voltage required for the single torque–speed operating point [V]
T
Motor torque [Nm]
n
Wheel rotational speed [rpm]
Ureq
Required voltage in the motor-model convention [V]
PWM
Voltage utilization factor, entered as percent but used as a fraction (85% = 0.85) [dimensionless]

This is the supply voltage required for one operating point on a curve; the headline minimum checks the larger of both project requirements. The horizontal amber line is selected DC supply voltage.

Solid diamond markers show the two required project points: target full torque at the target full-torque speed, and minimum torque at the target self-rotation speed. The cards below the chart show their torque, speed and required supply voltage. The larger required voltage determines the headline minimum supply voltage. Hollow circular markers, their callouts and vertical guides show the available torque at both input speeds, including target torque and controller current caps. If voltage limits positive torque, a point meets the supply line. If another cap applies first, it lies below the line. If back-EMF already exceeds the budget, torque is clipped to zero and the required-voltage callout can be above the supply line: that point is not feasible.

Green and blue rectangles use opposite diagonal hatching so that both remain distinguishable when their bounds coincide. They are visual bounds below selected voltage and left of the available-torque guides, not complete feasible regions. A feasible point must also be on or above its speed curve and respect current and torque caps. The supply is assessed at its horizontal voltage line. Stall below the chart means the capped torque at a stationary wheel.

← Back to calculator

Torque vs. FFBeast Power Limit

The horizontal axis is controller current setting [%]; the vertical axis is theoretical torque [Nm]:

T = Kt · Icontroller,max · PL / 100
T
Motor torque [Nm]
Kt
Torque constant in the current-amplitude convention [Nm/A]
Icontroller,max
Controller current corresponding to 100% Power Limit [A]
PL
FFBeast Power Limit setting expressed as a percentage [%]
100
Percentage scale: 100% represents the full configured current scale [%]

This chart does not apply voltage or speed restrictions. The target-torque line intersects the theoretical characteristic at Required Power Limit. Above 100%, that intersection is outside the shown controller range and a message replaces the marker. The linear characteristic omits magnetic saturation and temperature limits.

← Back to calculator

9. Abbreviations and conventions

FOC: field-oriented control. SVPWM: space-vector pulse-width modulation. PWM: pulse-width modulation. rpm: revolutions per minute. RMS: root mean square. DC: direct current. Power Limit: percentage of the configured controller maximum current.

The factors 0.75, 0.866 and 1.155 follow the assumed current and voltage definitions. Iq is current amplitude in the chosen FOC convention; resistance is measured line-to-line. The model omits inductance and controller dynamics. PWM denotes voltage utilization, not energy efficiency.

Six-step no-load speed is a separate estimate. The power result is not a global maximum across all speeds. These curves do not describe regenerative braking. Stationary-wheel torque is capped at the project target and controller limit and is not a continuous thermal rating.